| To divert any leak water out of the system over | | | | Remove the split-back film and lower the Leak |
| the roof deck protection using Weather Watch or | | | | Barrier around the pipe, be sure to press the |
| Storm Guard at plumbing vents or soil stacks. | | | | membrane firmly to seal it to the deck, to the |
| First install the Ice and water shield layer in an | | | | roof deck protection, and up the roof vent pipes |
| under and over placement as the residential steep | | | | sides. |
| slope roofing is a water shedding product not a | | | | For Advanced Installation Method: To divert any |
| water proofing product, Shingle-Mate or Deck | | | | water out over the roof shingles for laminated |
| Armor roof deck protection to within 6" of the | | | | shingles only this method cannot be used with |
| roof vent pipe. The Weather Watch or Storm | | | | three-tab shingles, install Shingle-Mate or Deck |
| Guard needs to be fully adhered to the roof | | | | Armor roof deck protection around the pipe. |
| plywood, OSB, or planking and should be fully | | | | Cut Weather-Watch or Storm Guard leak barrier |
| adhered to the succeeded courses of shingles to | | | | 20" minimum wide to surround pipes, shingle up to |
| properly expel the water to the roof below. | | | | the vent pipe, cutting the top of the shingle |
| Take the picture you see on the internet with a | | | | around the pipe, firmly press Leak Barrier over |
| grain of salt as they are not accurate to real | | | | the top half of the shingle in front of the vent |
| world practices of the way a shingle should be | | | | pipe then seal Leak Barrier to Shingle-Mate or |
| installed with ice and water shield. With standard | | | | Deck Armor roof deck protection and decking |
| strip shingles you need to install a diapered shingle | | | | above the vent pipe, finally cover roof deck |
| to prevent water from entering the water | | | | protection and leak barrier with shingle set in |
| groove or water eye. | | | | plastic cement. |
| Cut a 20" minimum square piece of Weather | | | | It is very important to have a Weather Stopper |
| Watch or Storm Guard leak protection | | | | Golden Pledge when installing a Weather Watch or |
| underlayment then place this piece over the | | | | a Storm Guard Leak Barrier around your homes |
| center of the pipe top. Cut an X from one edge | | | | plumbing vents. This is required on all Weather |
| of the pipe to the other, cutting this X slightly | | | | Stopper Golden Pledge installations and also when |
| smaller than the pipe width will allow a full seal | | | | installed or used on Weather Stopper System Plus |
| around the entire roof vent pipe. | | | | Installations. |